Here we are offering a Feutron Climate Test Chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climate range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climate operation: ± 1.0...± 1.5 K/min
Change rates
Heating: average 2.0 K/min
Cooling: average 2.0 K/min
The IEC 1646 standard is feasible with testing, solar modules up to a maximum weight of 160kg, and non-linear ramps (setpoint step).
Drying
Air drying: condensate drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95% r.h.
Temporal humidity deviation: ≤ ± 3.0...± 5.0 % r.h.
Dew point range: 8...80.9°C
Test chamber
Test chamber volume: 7.0 m³
Dimensions
Test chamber dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Hinged door DIN right, heated, l... Width 900 mm x Height 2100 mm
Observation window, heated, with darkening flap and lockable: Width 500 mm x Height 600 mm
Feed-through openings: 2x in the right front side, Ø 75 mm
Radiation Unit Test Chamber
Cut-out: 4x in the left side wall for SC 2500, each 850 x 700 mm
Irradiated area using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration Unit
Bitzer semi-hermetic 2-stage compressor, air-cooled
Condenser: split condenser (outdoor installation with winter control)
Refrigerants: R507 / R23
Temperature Control System
Itedpfxezd Sdgo Apysh
Cooling brine medium: Tyfocor / Water
Mixing ratio: 50/50%
Brine density: 1.072 kg/dm³
Fill volume: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply for test chamber
Electrical connection: 400V, 3/N/PE, AC, 50Hz
Connection type: fixed connection
Max. simultaneous power demand: approx. 32.0 kW
Feed line fuse: 3 x 63 A, Char C
Power supply for SolarConstant
Electrical connection: 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power demand: approx. 30.0 kW
Feed line fuse: 3 x 63 A, Char C
External dimensions of the complete test chamber including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/Control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber, total: approx. 2700 kg
Weight, condenser only: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (See photo)
(Subject to changes and errors in technical data and specifications!)
For further questions please contact us by telephone.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climate range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climate operation: ± 1.0...± 1.5 K/min
Change rates
Heating: average 2.0 K/min
Cooling: average 2.0 K/min
The IEC 1646 standard is feasible with testing, solar modules up to a maximum weight of 160kg, and non-linear ramps (setpoint step).
Drying
Air drying: condensate drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95% r.h.
Temporal humidity deviation: ≤ ± 3.0...± 5.0 % r.h.
Dew point range: 8...80.9°C
Test chamber
Test chamber volume: 7.0 m³
Dimensions
Test chamber dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Hinged door DIN right, heated, l... Width 900 mm x Height 2100 mm
Observation window, heated, with darkening flap and lockable: Width 500 mm x Height 600 mm
Feed-through openings: 2x in the right front side, Ø 75 mm
Radiation Unit Test Chamber
Cut-out: 4x in the left side wall for SC 2500, each 850 x 700 mm
Irradiated area using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration Unit
Bitzer semi-hermetic 2-stage compressor, air-cooled
Condenser: split condenser (outdoor installation with winter control)
Refrigerants: R507 / R23
Temperature Control System
Itedpfxezd Sdgo Apysh
Cooling brine medium: Tyfocor / Water
Mixing ratio: 50/50%
Brine density: 1.072 kg/dm³
Fill volume: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply for test chamber
Electrical connection: 400V, 3/N/PE, AC, 50Hz
Connection type: fixed connection
Max. simultaneous power demand: approx. 32.0 kW
Feed line fuse: 3 x 63 A, Char C
Power supply for SolarConstant
Electrical connection: 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power demand: approx. 30.0 kW
Feed line fuse: 3 x 63 A, Char C
External dimensions of the complete test chamber including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/Control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber, total: approx. 2700 kg
Weight, condenser only: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (See photo)
(Subject to changes and errors in technical data and specifications!)
For further questions please contact us by telephone.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
İstek gönder
Telefon & Faks
+49 2861 ... ilanlar
İlanınız başarıyla silindi
Bir hata oluştu