Açıklama
Description
A mobile PCM thermal energy storage unit transports thermal energy (waste heat or process heat) using phase change materials (PCM). It stores heat via changes in aggregation state, enabling it to achieve two to four times the storage capacity of conventional water tanks within compact dimensions. This system can be transported using a swap body on a truck.
Gedpfxsylmbqj Ai Dsbn
Storage capacity: 1.3 MWh thermal energy
Key Functions & Features
Principle (latent heat): Storage media such as paraffins or salt hydrates melt at designated temperatures, absorbing substantial amounts of heat. This energy is then released at the same temperature when solidifying.
Capacity & Efficiency:
Thanks to energy storage via phase change without noticeable temperature increase, these tanks offer considerably greater operational range. A modern mobile PCM storage unit typically accommodates several megawatt-hours (MWh) of storage volume.
Areas of Application:
Perfect for industrial supply of heat networks to hospitals, schools, or swimming pools, or residential complexes. The container can be fully charged with surplus heat at, for example, a biogas plant, and then transported to the point of use for unloading. Ideal for operators of biogas plants or wood gas CHP plants, as well as industrial sites where waste process heat is available free of charge.
Technical Data
Maximum storage temperature: 75°C
Thermal storage capacity (gross): 1300 kWh
Charging/discharging power (max.): 800 kW
Electronics onboard: Data acquisition, monitoring, and transmission
Charging/discharging technology on unit
Environmental compatibility: non-toxic, pollutant-free disposal, recyclable
Connection: two DN50 flow and return hoses, leak-proof, insulated, quick coupling
Power connection: 400 V
Logistics configurations: standard container chassis, semi-trailer, swap body technology with twistlocks, trailer solution, movable thermal insulation cover
Dimensions: 6 x 2.55 x 2.58 m (L/W/H) (approx. 20 ft container)
Weight: 20 t
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
A mobile PCM thermal energy storage unit transports thermal energy (waste heat or process heat) using phase change materials (PCM). It stores heat via changes in aggregation state, enabling it to achieve two to four times the storage capacity of conventional water tanks within compact dimensions. This system can be transported using a swap body on a truck.
Gedpfxsylmbqj Ai Dsbn
Storage capacity: 1.3 MWh thermal energy
Key Functions & Features
Principle (latent heat): Storage media such as paraffins or salt hydrates melt at designated temperatures, absorbing substantial amounts of heat. This energy is then released at the same temperature when solidifying.
Capacity & Efficiency:
Thanks to energy storage via phase change without noticeable temperature increase, these tanks offer considerably greater operational range. A modern mobile PCM storage unit typically accommodates several megawatt-hours (MWh) of storage volume.
Areas of Application:
Perfect for industrial supply of heat networks to hospitals, schools, or swimming pools, or residential complexes. The container can be fully charged with surplus heat at, for example, a biogas plant, and then transported to the point of use for unloading. Ideal for operators of biogas plants or wood gas CHP plants, as well as industrial sites where waste process heat is available free of charge.
Technical Data
Maximum storage temperature: 75°C
Thermal storage capacity (gross): 1300 kWh
Charging/discharging power (max.): 800 kW
Electronics onboard: Data acquisition, monitoring, and transmission
Charging/discharging technology on unit
Environmental compatibility: non-toxic, pollutant-free disposal, recyclable
Connection: two DN50 flow and return hoses, leak-proof, insulated, quick coupling
Power connection: 400 V
Logistics configurations: standard container chassis, semi-trailer, swap body technology with twistlocks, trailer solution, movable thermal insulation cover
Dimensions: 6 x 2.55 x 2.58 m (L/W/H) (approx. 20 ft container)
Weight: 20 t