Nemli iklim dolabı, 34 litreWeiss
WKL 34/40 -40...+150°C
Nemli iklim dolabı, 34 litre
Weiss
WKL 34/40 -40...+150°C
Durumu
Kullanılmış
Konum
Borken 

Resimleri göster
Haritayı göster
Makineye ait bilgiler
- Makine tanımı:
- Nemli iklim dolabı, 34 litre
- Makine üreticisi:
- Weiss
- Model:
- WKL 34/40 -40...+150°C
- Durumu:
- mükemmel (kullanılmış)
Fiyat ve Konum
- Konum:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ara
Teklif detayları
- Listeleme kimliği:
- A204-92700
- Referans no.:
- 24870
- Son güncelleme tarihi:
- 10.11.2025
Açıklama
Weiss
Model: WKL 34/40
Weiss Climate Chamber, Air-Cooled
Temperature Range: -40°C to +150°C
Chamber Volume: 34 liters
Standard Installed Access Ports:
R1 NW 50 mm
L1 NW 120 mm
Internal Dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External Dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for Temperature Testing:
Temperature Range: -40°C to +150°C
Temperature deviation when stabilized (according to IEC 60068-3-5):
Temporal temperature fluctuation (at center of usable space): ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specifications for Climatic Testing:
Temperature Range: +10°C to +95°C
Humidity Range: 10 to 98 % RH
Temperature and humidity deviations (stabilized, per IEC 60068-3-5):
Temporal temperature fluctuation (center): ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation (center): ±3 to ±5 % RH
Operational Data:
Test Chamber Illumination: Halogen bulb 12V, 20W
Rated Voltage: 1/N / PE AC 230 V ±10%, 50 Hz
Rated Power: 1.8 kW
Rated Current: 8.0 A
Gedpfx Aaoxvpp Rsysui
Required fuse (customer-side): 16A slow-blow
Heat emission for air-cooled chambers:
Maximum heat dissipation to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important Note:
"The table shown in the photos is not included in the sale."
Your Safety as Buyer – Information for You!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Changes and errors in technical data and specifications excepted!)
We are happy to answer further questions by phone.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Model: WKL 34/40
Weiss Climate Chamber, Air-Cooled
Temperature Range: -40°C to +150°C
Chamber Volume: 34 liters
Standard Installed Access Ports:
R1 NW 50 mm
L1 NW 120 mm
Internal Dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External Dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for Temperature Testing:
Temperature Range: -40°C to +150°C
Temperature deviation when stabilized (according to IEC 60068-3-5):
Temporal temperature fluctuation (at center of usable space): ±0.3 to ±1 K, ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specifications for Climatic Testing:
Temperature Range: +10°C to +95°C
Humidity Range: 10 to 98 % RH
Temperature and humidity deviations (stabilized, per IEC 60068-3-5):
Temporal temperature fluctuation (center): ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation (center): ±3 to ±5 % RH
Operational Data:
Test Chamber Illumination: Halogen bulb 12V, 20W
Rated Voltage: 1/N / PE AC 230 V ±10%, 50 Hz
Rated Power: 1.8 kW
Rated Current: 8.0 A
Gedpfx Aaoxvpp Rsysui
Required fuse (customer-side): 16A slow-blow
Heat emission for air-cooled chambers:
Maximum heat dissipation to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important Note:
"The table shown in the photos is not included in the sale."
Your Safety as Buyer – Information for You!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Changes and errors in technical data and specifications excepted!)
We are happy to answer further questions by phone.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
İlk kayıt tarihi: 2012
İstek gönder
Telefon & Faks
+49 2861 ... ilanlar
İlanınız başarıyla silindi
Bir hata oluştu