Malzeme test makinesiZwickRoell, Schenk-Trebel
RME 250 kN
Malzeme test makinesi
ZwickRoell, Schenk-Trebel
RME 250 kN
EXW sabit fiyat KDV hariç
€7.300
Üretim yılı
1985
Durumu
Kullanılmış
Konum
Breitenbach 

Resimleri göster
Haritayı göster
Makineye ait bilgiler
- Makine tanımı:
- Malzeme test makinesi
- Makine üreticisi:
- ZwickRoell, Schenk-Trebel
- Model:
- RME 250 kN
- Üretim yılı:
- 1985
- Durumu:
- onarım gereklidir (kullanılmış)
- Işlevsellik:
- sınırlı işlevsellik
Fiyat ve Konum
EXW sabit fiyat KDV hariç
€7.300
- Konum:
- Breitenbach, İsviçre

Ara
Teklif detayları
- Listeleme kimliği:
- A211-70057
- Son güncelleme tarihi:
- 05.02.2026
Açıklama
Schenk-Trebel Material Testing Machine Type RME 250 kN
• Load frame and drive by Schenk Trebel, year of manufacture 1985, total height approx. 3.3 m. Traverse stroke approx. 2 m
• Modernization around late 2003: Equipped with ZwickRoell "testControl" control electronics
• Retrofit in 2010: ZwickRoell Universal Extensometer System MultiXtens, with swivel device and two pairs of gauge arms (see photo), and new testControl module
• Information: The testControl module is compatible with the current "testXpert III" software from ZwickRoell (software not included in the scope of delivery)
• Temperature chamber, which can be inserted into the test area of the machine (see photo), built in 2006 by RS-Simulatoren Prüf- & Messtechnik; heatable up to approx. 200°C and can be cooled with liquid nitrogen down to approx. –40°C
• Load cells: 250 kN and 50 kN (currently installed, see machine photo); also included: 5 kN, 1 kN, and 500 N (see photo)
Cjdpfoyhb Rljx Afmegn
• 2 wedge specimen grips (see photo)
Machine Condition
The machine was used for testing up to early 2026. The following were in use during this time: the 50 kN load cell and the traverse displacement transducer (both sensors: last calibration 06.05.2024 incl. standard inspection). A fault in the servo amplifier for the drive (component of the testControl module) has, since approx. autumn 2025, frequently caused loss of connection to the software and stopped the drive until hardware and software are restarted. The servo amplifier or the entire testControl module must be replaced (cost information can be obtained from the supplier).
The 250 kN load cell was last calibrated on 11.02.2021 and has not been used for measurements since.
The other load cells, the MultiXtens system, and the temperature chamber have not been used or calibrated in recent years.
The two hydraulic clamping devices, which can be seen installed in the machine in the pictures, will be removed and will remain with the supplier.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
• Load frame and drive by Schenk Trebel, year of manufacture 1985, total height approx. 3.3 m. Traverse stroke approx. 2 m
• Modernization around late 2003: Equipped with ZwickRoell "testControl" control electronics
• Retrofit in 2010: ZwickRoell Universal Extensometer System MultiXtens, with swivel device and two pairs of gauge arms (see photo), and new testControl module
• Information: The testControl module is compatible with the current "testXpert III" software from ZwickRoell (software not included in the scope of delivery)
• Temperature chamber, which can be inserted into the test area of the machine (see photo), built in 2006 by RS-Simulatoren Prüf- & Messtechnik; heatable up to approx. 200°C and can be cooled with liquid nitrogen down to approx. –40°C
• Load cells: 250 kN and 50 kN (currently installed, see machine photo); also included: 5 kN, 1 kN, and 500 N (see photo)
Cjdpfoyhb Rljx Afmegn
• 2 wedge specimen grips (see photo)
Machine Condition
The machine was used for testing up to early 2026. The following were in use during this time: the 50 kN load cell and the traverse displacement transducer (both sensors: last calibration 06.05.2024 incl. standard inspection). A fault in the servo amplifier for the drive (component of the testControl module) has, since approx. autumn 2025, frequently caused loss of connection to the software and stopped the drive until hardware and software are restarted. The servo amplifier or the entire testControl module must be replaced (cost information can be obtained from the supplier).
The 250 kN load cell was last calibrated on 11.02.2021 and has not been used for measurements since.
The other load cells, the MultiXtens system, and the temperature chamber have not been used or calibrated in recent years.
The two hydraulic clamping devices, which can be seen installed in the machine in the pictures, will be removed and will remain with the supplier.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.